Sin number 3 - saving through neglect - wrong underlayment Do not lay the panels directly on carpets and other soft floor coverings. Installation on floating floors, such as layered boards and laminated panels, is possible, provided that underneath them it has been laid underlay with a parameter of CS = 200kPa and a vapor barrier of SD>75m. The panels can be laid on glued parquet, glued PVC and linoleum floor coverings, as well as on OSB or plywood floors, with no sagging and less than 10% moisture content in the wood. Arbiton panels can be installed on ceramic tiles, in this case, if the grout is wider than 4mm and deeper than 1mm, it should be filled with an appropriate mass (e.g. Vinyl panels are a good idea for renovation, so it should be taken into account that if we are laying panels on an existing floor, we must meet several conditions. The floor humidity can be checked with a meter, which can be borrowed from a construction equipment rental company. When installing vinyl panels on a floor with underfloor heating, the above-mentioned values must be 1.5% and 0.3% respectively. In the case of a cement screed, the moisture content in the substrate must be lower than 2.5%, and in the case of anhydrite screed, it must be lower than 1.5%. Pay attention to the humidity of the floor. If there are any unevenness, use cement leveling compounds or ready-made self-leveling compounds. The substrate should be even, flat and dry. The room where Arbiton vinyl panels will be installed must be swept and clean. The second sin - a poorly prepared subfloorīefore installation, vinyl panels should be acclimatized for a minimum of 24 hours at a temperature of 18–30 ° C in the room where they will be installed. Different types of locking system, even from the same manufacturer, require different assembly techniques. Vinyl panels from different manufacturers have completely different methods of installation. the Arbiton movie) or recognized professionals. Before starting work, it is highly useful to watch instructional videos, here we recommend the channels of producers (e.g.

Valinge locks are connected completely differently depending on whether we are dealing with 2G or 5G locks. Even the locks of one company require a different connection technique, e.g. It used to be common to hammer the panels together to better connect the rows, today it is forbidden in many cases and may result in irreversible damage to the panels. Modern locks are profiled with extreme precision, joining does not require force, only the appropriate technique. We currently have at least a dozen locking systems on the market. Locks in all types of panels are always the most sensitive element. Professionals know that laying panels from different companies may require a different preparation of the substrate or the technique of joining the locks. It is not enough to have a look, see the pictograms, because “I have installed some "panels" in my life already, I know what I am dealing with”.
#Laying a vinyl floor manual
Whoever reads the assembly manual sins less when it comes to installing a vinyl floor. Original sin - it is a waste of time to read the assembly instructions

For both groups tips below will come in handy.

Those who already have their first mistakes, sometimes costly, behind them and do not want to repeat them again, and those who want to be careful to prepare for the installation of Arbiton vinyl flooring before the purchase. Two types of visitors are reading this article.